Product Details:
Payment & Shipping Terms:
|
Product Name: | Digital Multifunction Meter | Application: | Monitor The Electrical Parameters |
---|---|---|---|
Feature: | Built-in RS-485 Panel-Mount | Type: | Single Phase |
Dimensional Size: | 96 X 96 X 86mm | Power Supply: | 24~80VAC/DC, 85~265VAC/DC |
High Light: | digital voltage panel meter,digital electricity meter |
Panel-Mount Digital Voltage Panel Meter Single Phase 2 Energy Pulse
Description
With modular design, MDM3001S has been applied in monitoring the
electrical parameters in single phase, 3 ph 3/4 wire electrical system.
Main features
Measure and analyze real time data, such as U, I, In,P, Q, S, cosΦ,
F, kWh, kvarh, etc.
Built-in RS-485 communication port
2 energy pulse output (active and reactive energy each)
Max/min. data record, and demand record
1 channel programmable analog output (4~20mA or 0~5V, optional)
Multi-tariff function (Max.12 Time slots, optional)
1 channel remote signal input (optional)
Measurement Accuracy
Parameters |
Display |
Direction |
Accuracy |
Voltage |
0~9999kV |
|
Class0.2 |
Current |
0~9999kA |
|
Class0.2 |
Power factor |
-1~+1 |
Directional |
Class 1 |
Frequency |
45~65Hz |
|
0.01Hz |
Active Power |
-9999~9999Mw |
Directional |
Class0.5 |
Reactive Power |
-9999~9999MVAr |
Directional |
Class0.5 |
Apparent Power |
0~9999MVA |
|
Class0.5 |
Active Energy |
0~9999999.99MWh |
Directional |
Class 1 |
Reactive Energy |
0~9999999.99MVArh |
Directional |
Class 2 |
Technical Specification
Current Input |
||||
Input Current:0~5A (Current value can be set up) Measurement scope:0.5%~120%In Overload capacity:2 X rated continuously,100A/1s non continuously Power consumption:≤0.2VA per phase |
||||
Voltage Input |
||||
Input Voltage:0~400VAC (L-N),0~693VAC(L-L)(Voltage value can be set up) System frequency:45~65Hz Measurement scope:3%~120%Un Overload Capacity:2 X rated continuous, 2500V/1s non continuous Power consumption:≤0.5VA per phase |
||||
Switch Status (optional) |
||||
Input Channels: Input Type: Isolated Voltage: |
1 channels Dry contact 2500VAC |
|||
Analog Output (optional) |
||||
No. of outputs |
1 channels programmable |
|||
Output signal |
4~20mA or 0~5V |
|||
Response time |
≤400ms |
|||
Pulse Output (standard) |
||||
No. of outputs |
2 channels(active/reactive energy each) |
|||
Serial com. Port (standard) |
||||
No. of outputs |
1 RS-485 port |
|||
Communication protocol |
Modbus-RTU protocol |
|||
Baud rate |
2400,4800,9600,19200,38400 bps |
Other parameters
Operation temperature:-20℃ ~ +60℃
Storage temperature:-40℃ ~ +85℃
Operation humidity:5~95%RH
Temp. drifting rate: <100ppm/℃
Total power consumption:<5VA
Auxiliary power supply: 24~80VAC/DC, 85~265VAC/DC
Voltage resistance(Input against Output); 2500V/1min.
Material of Housing: Flammability acc. to UL 94V0
Dimensional Size: 96mmX96mmX86mm
Installation Size: 91mmX91mm
Contact Person: Miss. Maple
Tel: +86 0755 83426356