M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz

large.img.alt
small.img.alt

Large Image :  M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz Get Best Price

Product Details:
Place of Origin: China
Brand Name: Artel
Model Number: M60-1S
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Wooden box
Delivery Time: 1 month
Payment Terms: TT
Detailed Product Description
High Light:

overload protection relay

,

motor protection circuit

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz

 

 

Profile

 

M60 protection controller is designed to provide full-scale protections and controls of low-voltage asynchronous motor and increasing safety motor rated below 800A, 50Hz, 380VAC. M60 measures the electrical parameters of motors, operates and controls the motors ,and equipped with the history record management and remote communication function.

M60 products portfolio: standard M60-1S and M60-3S, popular M60-2M and integrated M60-2P. With different infrastructure, installation, and functions, these four types of protector controllers can meet different requirements of customers in low-voltage protection area.

 

 

Features

 

Variety of product portfolio to suit customers' needs

Recording function to record the instant data before and after the faults for fault analysis purpose

Flexible protection functions configuration to ensure the safe and continuous production

Automatic software and hardware inspection to increase the stability and reliability

Remote or local operation on parameters setup, motor start, stop, and reset

Detection on the motor start status automatically to avoid malfunction

Configured with large size LCD panel for on-site operation (optional)

 

Technical Specification of M60-1S

Input (M60-1S)

Input Current: 5A

Remote digital signal input: 1 channel (dry contact)

 

Output (M60-1S)

RS-485 output: 1 channel

Analog output: M60-1S, 1 channel (4-20mA or 0-5V)

            Relay output: 2 channels (dry contact)

Contact capacity of control output relay: 10A/250VAC

Contact capacity of alarm output relay: 10A/250VAC

 

Measurement Record (M60-1S)

Accuracy: I, class 0.5

Accumulated operating time on record (Max.): 9999days

 

Size & Weight: (M60-1S)

Installation: Panel mounting

Dimensional size: 96mmX48mmX76mm

Installation size: 94mmX46mm

Weight: 450g 

 

Environment

Auxiliary power supply: 85~265VAC/DC

Total power consumption: <3VA(M60-1S/3S )

                      

Operation temperature: -20℃ ~ +60℃

Storage temperature: -40℃ ~ +85℃

Operation humidity: <90%RH

Storage humidity: <95%RH

 

 

Protection Function:

 

Function

Status

Item

Content

M60-1S

M60-2S

M60-2M

M60-2P

Overtime start 

protection

Programmable

Allowed 

startup time

0-80s

Yes

Yes

Yes

Yes

Protection 

method

2

Short circuit protection

Programmable

Fault setting

 range

4-12le

Yes

Yes

Yes

Yes

Execution 

delay time

0.1-0.5s

Protection 

method

0, 2

Locked rotor protection

Programmable

Fault setting 

range

200-950%le

Yes

Yes

Yes

Yes

Warning

 setting

 range

150-255%le

Execution 

delay time

0.1-25.5s

Protection 

method

0, 1, 2, 4

Underload protection 

Programmable

Setting 

range

20-95%le

Yes

Yes

Yes

Yes

Execution 

delay time

0.1-60s

Protection 

method

0, 1, 2, 3

Overload protection

Programmable

Setting range

105-150%le

Yes

Yes

Yes

Yes

Execution 

delay time

0.1-250s

Protection 

method

0, 1, 2, 3, 4

Thermal by overload 

Must

Setting 

range

1-105%θb

Yes

Yes

Yes

Yes

Protection 

method

4

tE time protection

 (Increased Safty Motor)

Programmable

tE time

1.0-15s

Yes

Yes

Yes

Yes

Protection 

method

4

Unbalance protection 

(phase failure)

Programmable

Setting range

10%-60%

Yes

Yes

Yes

Yes

Execution 

delay time

0.1-30s

Protection 

method

0, 2, 4

Over power 

protection

Programmable

Setting 

range

101-120%Pe

 

 

Yes

Yes

Execution 

delay time

0.1-200s

Protection 

method

0, 1, 2, 3 

Under power

 protection

Programmable

Setting range

30-80%Pe

 

 

Yes

Yes

Execution 

delay time

0.1-200s

Protection 

method

0, 1, 2, 3

Over power

 factor protection

Programmable

Setting range

0.01-1.00

 

 

Yes

Yes

Execution 

delay time

0.1-25.5s

Protection 

method

0, 1, 2, 3

Under power 

factor protection

Programmable

Setting range

0.01-1.00

 

 

Yes

Yes

Execution 

delay time

0.1-25.5s

Protection 

method

0, 1, 2, 3

Phase reversal 

protection

Porgrammable

Execution 

delay time

0.1-25.5s

 

 

Yes

Yes

Protection 

method

0, 2

Under voltage 

protection

Programmable

Setting range

45-95%Ue

 

 

Yes

Yes

Execution 

delay time

0.1-200s

Protection 

method

0, 1, 2, 3 

Over voltage 

protection

Programmable

Setting range

101-120%Ue

 

 

Yes

Yes

Execution

 delay time

0.1-200s

Protection 

method

0, 1, 2, 3 

Leakage Current 

protection

Programmable

Setting range

10-500mA

 

 

Yes

Yes

Execution 

delay time

0.1-5s

Protection 

method

0, 1, 2

Overheat 

protection

Programmable

Execution 

delay time

0.5s

 

 

 

Yes

Protection 

method

0, 2

Interlock 

protection

Programmable

Execution 

delay time

0.1-60s

Yes

Yes

Yes

Yes

Protection 

method

2

Connection to 

ground protction

Programmable

Setting range

10-100%Ie

Yes

Yes

Yes

Yes

Execution 

delay time

0.1-5s

Protection 

method

0, 2

 

 

M60-1S

M60-3S

M60-2M

M60-2P

Control function

Direct start

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Reversing start

 

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Y-△Start

 

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Lower Voltage start

 

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Restart motors caused by Voltage fluctuation

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Emergency fault output

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Local/remote command of start, stop

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Measurement function

Operating Current 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Unbalanced Current ratio

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Voltage, frequency, power, power factor,leakage current

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

No. of contact executions

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Status of contacts

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Record Function

Latest 10 start/stop record

 

 

Clock

Clock

Latest 10 alarm record

No clock

No clock

Clock

Clock

Latest 10 trip record

No clock

No clock

Clock

Clock

Latest 10 restart record caused by Voltage fluctuation

 

 

Clock

Clock

Max. and min. parameters records in the protection execution 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Accumulated operating time of motor

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 0

Communication Function

RS-485 com. Port

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 33

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 34

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 35

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 36

Modbus protocol

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 37

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 38

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 39

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 40

Profibus protocol

 

 

 

M60 Protection Controller / Motor Protection Relay 1 Channel 800A 50Hz 41

 

 

Remark:

 

M60-3S performs the same function as M60-1S, except that M60-3S has built-in CT, M60-1S has exterior 

CT with 5A input.

 

 

Competitive advantage :


We can follow the Customer-oriented principle, Artel Tech. aims to innovate hi-tech products and provide comprehensive solutions continuously, and continue to offer qualified products and excellent services to its global customers.

Artel's successful strategy is reflected in the number of certifications, including ISO9001 and CE quality system certification, Software Enterprise certificate issued by National Information Department, and hi-tech company certificate issued by government, etc.

 

 

Contact Details
Shenzhen Artel Technology Co., Ltd.

Contact Person: Miss. Maple

Tel: +86 0755 83426356

Fax: 86-755- 83402232

Send your inquiry directly to us