Payment & Shipping Terms:
|
Product Name: | Meter Test Equipment | Application: | Static Electricity , EMC |
---|---|---|---|
Feature: | Modular Design, Strong Anti–interference Ability | Operation: | PC / Wireless |
Size: | 600mm(L)× 440mm(W)× 176mm(H) | Power Supply: | 90-265VAC/DC |
High Light: | portable testing equipment,Portable Appliance Testing Equipment |
8 Inch Color Touch Screen Power Measurement With PC / Wireless
Main function:
Used for various tests of analog and digital AC Voltage meter and Current meter, Single/three phase
active and reactive power meter, Phase angle meter, Single/three phase power factor meter, frequeny
meter, and synchronous meter, Single/three phase active and reactive power meter; Output 2nd ~63rd harmonics;
Profile:
AT3020 is suitable for the measurement departments of research institution, power grid corporation and
railway, national measurement institution at all levels, and the test, production and inspection of meter
manufacturer.
Main features:
Type:
AT3020C 3-phase AC Power Source (50A), Class 0.05
AT3020B 3-phase AC Power Source (50A), Class 0.1
Technical Specification
AC Voltage Output
Range: 100V, 220V, 380V, 660V;
Adjustment Range: (0~120) %RG; RG refers to range, similarly hereafter;
Adjust resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;
Stability: 0.005%/1min (Class 0.05), 0.01%/1min (Class 0.1)
Distortion: ≤0.1% (Non capacitive load);
Max output load: 25V /phase (resistance load);
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
AC Current output:
Range: 0.05A, 0.2A, 1A, 5A, 16.67A, 50A;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter;
Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 50VA (50A range)
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Power output
Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Phase output
Output adjusting range: 0°~360°;
Output adjusting resolution: 10°, 1°, 0.1°, or 0.01°;
Resolution: 0.01°;
Power factor output:
Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
Frequency output
Adjusting range: 40Hz ~70Hz;
Output adjusting resolution: 1Hz, 0.1Hz, 0.01Hz, or 0.001Hz;
Resolution: 0.001Hz;
Accuracy: 0.001 Hz.
Harmonic setting
Harmonic order: 2nd ~63rd
Harmonic amplitude: 0~40%
Harmonic angle: 0°~359.99°
Harmonic set error: 2nd ~31st : ≤±0.1%,32nd ~63rd : ≤±0.2%;
Energy error measurement:
Active energy basic error limit:
±0.05%RD (Voltage 15V~660V, Current 0.02A~60A, PF≥0.5);
±0.1%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);
Reactive energy basic error limit:
±0.1%RD (Voltage 15V~660V, Current 0.02A~60A, PF≥0.5);
±0.2%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);
Other parameters:
Power supply: 90-265VAC/DC
Power frequency: 50Hz~60Hz
Power consumption: 50VA~1000VA
Environment condition: 20℃~30℃,Humidity: RH≤85%
Storage environment: -20℃~50℃
Size: 600mm(L)× 440mm(W)× 176mm(H)
Weight: 28kg
Contact Person: Miss. Maple
Tel: +86 0755 83426356
Fax: 86-755- 83402232